Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Connector (M12).
Sensing distance: 100 mm (wide view).
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Model: CPM2A-20CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 12 points.
Outputs points: 8 points.Output: DPDT.
Lighting: Non-lighted
K3NC-NB2A-T2
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. E32-D61 type: environment resistant; heat resistant,
Specialty: heat resistant: 350,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsNumber of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.