Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
K3NH-TA2A-C1
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. CPU Unit: CP1H-X CPU Units.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 24; Output, 16.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. Cable: PUR.
Cable core number (core): 3.
Cable outside diameter: 4.3mm.
Cable outlet direction: L type.
Cable length L:5m.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67.
FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance,
Reduce equipment downtime.
IEC61076-2-101 (IEC60947-5-2).
For LED products, can clearly confirm the status of the sensor action.
K3NH-TA2A-C1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NH-TA2A-C1&select=5