Output: DPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
K3NR-PB1A-FLK5
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Output: SPDT.
Lighting: LED.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Actuator: Pin plunger.
Type: M16.
Operation Indicator: None.
Repeat accuracy: 3 µm max.
Operating force OF max: 2.45 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance. Cable type: Standard Cables.
Type: Cable with Plug on One End (M12 Right-angle) .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: None.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
K3NR-PB1A-FLK5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NR-PB1A-FLK5&select=5