CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 100 VAC CV500-FHD01-EDetect errors in motors and other equipment,
through current changes.
Monitor for overcurrents and undercurrents,
simultaneously with one Relay.
Monitor AC or DC currents with one Relay.
Use with commercially available CTs (CT secondary side: 0 to 1 A or 0 to 5 A).
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work
K3NX-AA2A-FLK3
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 12 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Size: M30, Non-shielded.
Sensing distance: 20.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 44 (58)(See note.).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.
K3NX-AA2A-FLK3 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NX-AA2A-FLK3&select=5