Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block
LY2F-HIA AC240
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 21.
Protective height: 1020mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 3.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).
LY2F-HIA AC240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LY2F-HIA AC240&select=5