LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
MK2PA DC24 Pirce
No PHOTO
OMRON MK2PA DC24
Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 200V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape MK2PA DC24
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Model: C200H-OC224N.
No. of points: 8 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads)Independent commons.Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 100 W.
Output voltage: 12 V.
Output current: 8.5 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
MK2PA DC24 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=MK2PA DC24&select=5


...more relevant model market price >>>>
Related products
OMRON
Slim I/O Relay
G3RV-SR700-AL DC24
OMRON Slim I/O Relay G3RV-SR700-AL DC24
Terminal wire connection: Screw termin
OMRON
Solid State Relays
G3FM-2R5SLN DC24
OMRON Solid State Relays G3FM-2R5SLN DC24
Isolation: Photo-voltage coupler. Zero
OMRON
I/O solid state relay
G3TA-OA202SZ DC24
OMRON I/O solid state relay G3TA-OA202SZ DC24
Type: output module. Insulation mode: t
OMRON
Voltage Sensor
LG2-DB DC24
OMRON Voltage Sensor LG2-DB DC24
Detected voltage: DC. Compact, Economic