Appearance: T-shaped, slot center 10 mm.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements
MK3P5-I-VD DC48
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations.
Connector with lock that mates with commercially available,
connectors. Terminal: Solder terminal (-1A).
Actuator: Hinge roller lever; High OT.
DPDT Basic Switch for Two.
Independent Circuit Control.
Ideal for switching the circuits operating on two,
different voltages, and for controlling two independent circuits.
Interchangeable with OMRON Z Basic Switches,
as both switches are identical in mounting hole,
dimensions, mounting pitch and pin plunger position. Operation: Push operation, Self-reset; Pull operation, Hold.
Built-in Switch: V-15-1B6.
Door Switches with Built-in Basic.
Switches for Long Life.
Installation in electrical facilities, equipment doors, and other,
openings helps ensure safety by reliably preventing accidents.
A Basic Switch if built in to provide a large switching capacity,
and long service life. Case color: Light gray.
Lighting method: Incandescent lamp; 28 VDC/VAC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
MK3P5-I-VD DC48 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MK3P5-I-VD DC48&select=5