Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Manual.
Output: SPST-NC + SPST-NC.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature
MKS1TI-10 AC230
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle).
Cable length: 5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Item: Mark-detecting models(multiple color light sources); Blue LED.
Functions: Timer, Response speed change.
Model: NPN output.
Advanced Fiber Amplifier Units.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs.
2-channel models achieve the thinnest* profile in the industry,
at only 5 mm per channel.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit. Name: Temperature Control Module.
Model: C200H-TC002.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Voltage output.Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-C.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
MKS1TI-10 AC230 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS1TI-10 AC230&select=5