OMRON MKS2PIN DC110
Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Response time: 1 ms.
Sensing distance: 15 m (300 mm) (Using E39-R1),
7 m(200 mm)(Using E39-R12), 7 m (200 mm)(Using E39-R6) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color MKS2PIN DC110
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.050 A; 60 Hz, 0.040 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25.0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Contact form: SPST-NO/SPST-NC.
Type: Standard Models.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load).
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).
MKS2PIN DC110 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=MKS2PIN DC110&select=5


...more relevant model market price >>>>
Related products
OMRON
General-purpose Relays
MKS2PI-2
OMRON General-purpose Relays MKS2PI-2
Type: Standard Models. Terminals: Plug-
OMRON
General-purpose Relays
MKS2PIN
OMRON General-purpose Relays MKS2PIN
Type: Standard Models. Terminals: Plug-
OMRON
General-purpose Relays
MKS2PIN1
OMRON General-purpose Relays MKS2PIN1
Type: Standard Models. Terminals: Plug-
OMRON
General-purpose Relays
MKS2PI
OMRON General-purpose Relays MKS2PI
Type: Standard Models. Terminals: Plug-