Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
MKS2PN-V-2 AC230
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Spring-cage terminals.
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately).
MKS2PN-V-2 AC230 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS2PN-V-2 AC230&select=5