Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
MY2Z-G DC12
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Timer input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Model: CPM2C-10C1DTC-D. CPU Unit: Units with 10 I/O points.
2 Fujitsu connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: Yes.Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.
MY2Z-G DC12 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MY2Z-G DC12&select=5