LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
OTG-N104 600A Pirce
No PHOTO
OMRON OTG-N104 600A
Name: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC OTG-N104 600A
Input type: Analog (Current, Voltage) Input Type.
Control method: Valve Control.
Number of alarms: None.
Communica- tions function: None.
Event input: None.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.
OTG-N104 600A Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=OTG-N104 600A&select=5