Number of beams: 31.
Protective height: 320mm.
Model: NPN output.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC
PY08QN2-Y1
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Box protection class: metal, IP00.
Terminal size: M8.
Line diameter: 30 square mm.
Weight: 4.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 200 mm.
Functions: --.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
PY08QN2-Y1 Operation manual/Instructions/Model selection sample download link: