Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
A165-JAM-14mm).
Without harmful substances to the environment, the lead type has also been lead-free. Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output: PNP.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Connects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS02.Model: C200H-ME831.
Description: EEPROM, 8K words, no clock.Power supply voltage: DC.
Sensing method: Retro-reflective without MSR function.
Sensing distance: 7 m[100 mm](When using E39-R1).
Output configu ration: NPN.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
A165-JAM-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A165-JAM-1&select=5