Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Type: printing plate mounting type, with left column.
Driving rod: long swing rod type.
Terminal specification: printed board, angular.
Contact specifications: 1c
A165L-TGM-24-1
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Appearance: Standard sound.
w/jumper direction A *2: Intermittent(short).
w/jumper direction B *2(w/o jumper): Intermittent (long).
Supply voltage: 12 to 24 VAC/VDC.
Buzzer Unit Series with Cylindrical.
22-mm × 16-dia. Body.
Lineup includes standard-volume models (80 phons, constant) and,
high-volume models (70 to 95 phons, variable). Intermittent or,
continuous sound can be selected. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
A165L-TGM-24-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A165L-TGM-24-1&select=5