Item: Advanced models, Twin-output model.
Functions: Area output, open circuit detection, differential operation.
Communications Unit Applicable Sensor: E3X-ECT, E3X-CRT.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads
A16L-JGA-T2-2S
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Input capacity: 32 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
A16L-JGA-T2-2S Operation manual/Instructions/Model selection sample download link: