Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 15 W.
Output voltage: 12 V.
Output current: 1.3 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
A22L-DY-T2-11A
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 150W.
Output voltage: 48VDC.
Output current: 3.3A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Category: incidental cover with under voltage detection function.
Structure: bottom mounting type.
Capacity: 50W.
Output voltage: 24V.
Output current: 2.2A.
Alarm output: leakage type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
A22L-DY-T2-11A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-DY-T2-11A&select=5