Size: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Model: C200H-ID211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VDC, +10%/–15%.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED
A22L-TY-24A-11M
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: 10mProduct name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
320 points/10 Units (No Expansion Rack); Program capacity,
10K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Type: cross screw type.
IO points (number of poles): 32 (34).
The PLC connection type and the rich polar number of PLC are specially connected.
PLC connection type for the use of OMRON and MITSUBISHI motor,
PLC (plant) production of specialized connection wiring mode, to facilitate the confirmation signal configuration.
In addition, the terminal table record PLC address on the label.
Universal type for a variety of connectors, the number of species.
Connection with cross recessed screws, slotted screw type and insertion type.
DIN guide rail and screw can be used to install.
Terminal arrangement fully considers the maneuverability, makes the connection operation become easy and simple.
The operability of the plug-in terminal can be improved (XW2F comparison of the company).
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
A22L-TY-24A-11M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-TY-24A-11M&select=5