Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: SPDT.
Lighting: LED, 24 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation
A22RL-FA-24A-02M
Easy panel mounting from the front and simple lamp replacement.
without tools. Actuator: Roller plunger.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type: Medium-sensitivity models.
Sensed current: 200 mA/500 mA(switchable).
Type: High-speed models.
Operating time: Less than 0.1 s.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Product name: Conductive Level Controller.
Model number: Open collector (NPN).
Battery (24 VDC) allows use in locations.
without AC power supply. AC sine-wave.
voltage between electrodes enables stable.
detection with no electric corrosion.
Outputs can be set to self-hold at ON or OFF using special circuits.
Adjustable sensitivity, with an operating resistance range of 0 to,
100 kΩ, allows use for a wide variety of liquids.
Relay contact chattering conventionally caused by waves elim,
inated using open collector output, reducing contact wear.
Meets CE marking and is a UL recognized component.
A22RL-FA-24A-02M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RL-FA-24A-02M&select=5