Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
A22TK-2LL-01-07
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: SPDT.
Lighting: Incandescent lamp; 6 VDC/VAC.
Pushbutton color symbol: 2.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Type: 1a1b welding terminal.
Shape: square.
Type: General load.
Motor function: alternate action (self retaining).
With light: LED with light.
Using voltage: DC5V.
Operation Department color: green.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
A22TK-2LL-01-07 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22TK-2LL-01-07&select=5