Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 3000mm; B, 2750mm.
Output use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Power rating: 100 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 85 to 132 VAC,
176 to 264 VAC, or 248 to 373 VDC(Select with the switch.).
Output voltage: 12 V VDC
A22TK-2LR-21-K01
Output current: 8.5 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: shield, M12.
Detection range: 3mm.
Action mode: NO. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1.25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.30A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.