Classification: General purpose Models.
Description: Sheathed thermocouple.
Temperature range (See note 3.): 0°C to 900°C.
Element type: K (CA) J (IC).
Conductor type: Non grounded type.
Class: 2 (0.75).
Protective tubing material: ASTM316L.
Terminal type: Exposed terminals.
Page: 13.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
A22TK-2RR-03-06
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Number of poles: 3 poles.
Classification: Models with single contacts.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 24 VDC;
Made-to-order items, 12, 24, 110/120, or 220/240 VAC, 12, 48, or 100/110 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A22TK-2RR-03-06 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22TK-2RR-03-06&select=5