Applicable CPU Units: CQM1H-CPU51/61.
Connection location and number of Units: One Unit only.The Unit must be connected between the Power Supply Unit and the CPU Unit.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 170 g max.Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Roller leaf spring.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy
A22W-3MY-T2-11
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Unit type: CS1 Basic I/O Units.
Product name: AC Input Unit.
Specifications: 100 to 120 VAC,
16 inputs 100 to 120 VDC, 16 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No.
Words required: (I/O bits: CIO 0000 to CIO 0319), 1 word.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: DPDT.
Lighting: Incandescent lamp; 28 VDC/VAC.
Pushbutton color symbol: 2.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: E5CZ-C2MD.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
A22W-3MY-T2-11 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22W-3MY-T2-11&select=5