The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -
A3AT-90B1-00B
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Appearance: Round/Full-guard type A22-G.
Output: SPST-NC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Power ratings: 240 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 48 V.
Output current: 5 A.
Boost Current: 6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.