Number of beams: 42.
Protective height: 840mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module
A3AT-91B1-00EG
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Shape: socket (with open end cap).
Pole number: 50.
Pole pole number: 1.
Minimum packing unit: 40.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Appearance: Unshielded, M30.
Sensing distance: 18 mm.
Model: Operation mode, NC.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs.
A3AT-91B1-00EG Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3AT-91B1-00EG&select=5