Type: no wing.
Drive shaft type: semi cylindrical plug type.
Outlet hole: side 2.
Even number: 2.
Rubber material: NBR.
Head and body integration, strength and sealing performance is better, mechanical life is also significantly increased (5 million times).
The most suitable for a variety of machine tools, automatic production line of the order control.
With drain holes, oil and water can be discharged after immersion
A3PJ-4003 Control output: Voltage output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnot: Detection for Single-phase heater.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
A3PJ-4003 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3PJ-4003&select=5