Appearance: Rectangular (M16-A).
Lighting: LED without Voltage Reduction Unit, 12 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting
A3PJ-90B11-24EW
Input voltage: 35W.
Output voltage: 24VDC.
Output current: 1.5A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Number of beams: 86.
Protective height: 1720mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A3PJ-90B11-24EW Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3PJ-90B11-24EW&select=5