Inverter input power: 3 phase / single phase AC200V.
Weight: 3.6KG.
Standard applicable line diameter: 8 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch
A3SJ-90A1-28R Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.