Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: Pg13.5.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened
A6SN-0104-P The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1). Appearance: Round/Projection type LED voltage-reduction lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Applicable model (typical example): MY4.
New Screwless Terminal Sockets Added.
for MY and G2R Relays.
Simplified wiring without tightening screws.
Two wires can be independently wired for each terminal.
Coil terminals and contact terminals are completely separated,
in an organized wiring layout.
Release Levers and Nameplates are available (sold separately). Unit classification: CJ1 Special I/O Units.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface: Pulse-train open-collector,
output with Pulse Counter Function;
Number of control axes : 2 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.27A; 24V, --.
Standards: UC1, CE.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed.
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors.
A6SN-0104-P Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A6SN-0104-P&select=5