Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output)
A8G-107-1-24
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: slotted screw type.
IO points (number of poles): 34.
The PLC connection type and the rich polar number of PLC are specially connected.
PLC connection type for the use of OMRON and MITSUBISHI motor,
PLC (plant) production of specialized connection wiring mode, to facilitate the confirmation signal configuration.
In addition, the terminal table record PLC address on the label.
Universal type for a variety of connectors, the number of species.
Connection with cross recessed screws, slotted screw type and insertion type.
DIN guide rail and screw can be used to install.
Terminal arrangement fully considers the maneuverability, makes the connection operation become easy and simple.
The operability of the plug-in terminal can be improved (XW2F comparison of the company).
A8G-107-1-24 Operation manual/Instructions/Model selection sample download link: