CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP227.
8-MB memory; w/floating-point processor.Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function
B3F-1025S
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Display contents: Decimal.
Type: Rear mounting.
Logic input: Negative.
Display color: Red.
Digital Display with Wire-saving Serial.
Transmission Function (B7A Output).
Single-color (red or green) and three-color (red, green, or,
orange selectable) displays with a character height of 80, 120,
or 200 mm are available for a variety of applications and locations.
Thin design with a 39.5-mm depth for the 120-mm model is,
perfect for saving space in equipment and devices.
Decimal display including negative sign (−) display with signal,
codes is possible. Type of input: AC current input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth
B3F-1025S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=B3F-1025S&select=5