Classification: High-sensitivity.
Contact gap: H (0.25 mm).
Actuator: Slim spring plunger.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available
C500-DA103
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Action indicator: built-in type of mechanical indicator.
Number of contacts: 2 pole.
Operating coil voltage: AC100/110V.
Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator).
Suitable for environmental protection RoHS.
Conforms to the UL, CSA, IEC (VDE) standardOperation indicator: With operating indication; Standard load.
Ratings: 4 A at 30 VDC.
Actuator: Adjustable roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
C500-DA103 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=C500-DA103&select=5