Product name: N@@-type CPU Units with 40 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 24; Outputs, 16;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality
CPM2B-32EDR
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
CPM2B-32EDR Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=CPM2B-32EDR&select=5