Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
CQM1-ME08K Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Type: 2-Conduit.
Contact configuration: Slow-action; 1NC/1NO.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Models with diode for coil surge,
absorption (DC coil specification only).
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).
CQM1-ME08K Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CQM1-ME08K&select=5