I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Pulse I/O: YES.Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 8 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Type: 1a1b welding terminal.
Shape: square.
Type: General load
D2MSL
Action: instantaneous action (auto recovery).
With lamp: no light.
Operation Department color: white.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Type: Reverse wiring.
Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Type: High-speed response models.
Connecting method: Pre-wired (2 m).
Model: PNP output.
Applicable wire-saving connector(sold separately): Type,--; Model,--.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximately 20 years.
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even for low-reflective objects and large objects.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
D2MSL Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D2MSL&select=5