LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
D2MV-1L111-1C3 Pirce
No PHOTO
OMRON D2MV-1L111-1C3
Type: Welding / wire type, with right column.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, the left side.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 D2MV-1L111-1C34mm).
Without harmful substances to the environment, the lead type has also been lead-free. C500-ID I/O Unit DC Input 16 pts C500-ID213(3G2A5-ID213).
DC12-24V 10mA.Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Appearance: Round/Projection type A22-T.
Output: SPST-NO + SPST-NC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
D2MV-1L111-1C3 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=D2MV-1L111-1C3&select=5


...more relevant model market price >>>>
Related products