LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
3G2A5-AD002 Pirce
No PHOTO
OMRON 3G2A5-AD002
Model: CPM2C-32CDT1M-D. CPU Unit: Units with 32 I/O points.
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) 3G2A5-AD002
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
3G2A5-AD002 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=3G2A5-AD002&select=5


...more relevant model market price >>>>
Related products
OMRON
Output Unit
C500-OD211(3G2A5-OD211)
OMRON Output Unit C500-OD211(3G2A5-OD211)
C500-OD I/O Unit Transistor Output 64 pt
OMRON
AC Input Module
C500-IA122(3G2A5-IA122)
OMRON AC Input Module C500-IA122(3G2A5-IA122)
C500-IA I/O Unit AC Input 32 pts C500-IA
OMRON
Output Unit
C500-OD217(3G2A5-OD217)
OMRON Output Unit C500-OD217(3G2A5-OD217)
C500-OD I/O Unit Transistor Output 16 pt
OMRON
High-speed Counter Module
C500-CT001(3G2A5-CT001)
OMRON High-speed Counter Module C500-CT001(3G2A5-CT001)
C500-CT/3G2A5-CT Special I/O Unit High-s