Illumination: LED.
Rated voltage: 24 VAC/VDC.
Pushbutton color: Red.
Pushbutton size: 40 dia.
Terminal: Solder terminal.
Contact form: SPST-NC.
Separate Construction with Smallest.
Class of Depth in the World.
Direct opening mechanism to open contacts in emergencies,
such as when they are welded.
Conforms to EN 60947-5-5.
Includes a safety lock to prevent misuse.
Features separate construction that allows the Switch to be,
separated for easier wiring and one-piece construction that,
allows easier handling
3G2A5-RM201
Models available with 3 contacts built into a single block (A165E-U). Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-R1TC;
Resistance thermometer input, E5GN-R1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Servo trunk unit.
Product Name: servo relay unit.
Application unit: FQM1-MMA22/MMP22, CS1W-HCP22-V1.
Specifications: -.
Axis number: biaxial.
The connector and terminal of the relay unit are integrated into a whole,
Save the wiring servo drive and position control unit.
Servo driver and control signal of position control unit,
Simple wiring on terminal stage.
The connector without soldering, with only a screwdriver can wiring.
Dedicated connection cable between units.
DIN guide rail installation, the rapid installation, screw installation of two methods.
M3.0 thread terminals attached with a special plate signal.
The terminal can be confirmed by the signal name.
3G2A5-RM201 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G2A5-RM201&select=5