Type: rectangle.
Screen mode: level 2.
Using voltage: DC5V.
Color: white.
Color: white.
Micro design, the length of the body is only 23mm.
LED has five colors (red, yellow, green, white, and blue).
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode
3G3JZ-AB004
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. E3JK-R4M1 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 5m.
Output status: ON.
Output: relay,
2 types of cost reductionName: HFU with DeviceNet Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None.
Communications functions: DeviceNet communications.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
3G3JZ-AB004 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G3JZ-AB004&select=5