E32-T12R type: standard type; soft (new standard),
Specialty: diameter 3 cylinder,
Shape / detection distance (mm): 700; 530; 350 (140),
Standard test object
(minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsRelease key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC
70066-1132 KEX13(I)
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Type: Standard Models.
Terminals: Plug-in.
Contact form: DPDT.
Internal connections (See note 3.): Non-standard.
With mechanical indicator.
Coil ratings: AC/DC.
New Super MK Relays.
Models with Latching Lever Added to the Series.
Same mounting and internal wiring as the previous Super.
MK Relays.
Built-in mechanical indicator enables checking contact operation.
Two modes can be used to check circuits for models with latching lever.
Nameplate provided on models with latching lever.
All materials are RoHS compliant.
UL and IEC (TÜV) certification. Model: Shielded, M8.
Sensing distance: 1.5 mm.
Output configuration: AC 2-wire.
Model: Operation mode, NC.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Appearance: Rectangular (M16-A).
Lighting: Incandescent lamp, 5 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch.
70066-1132 KEX13(I) Operation manual/Instructions/Model selection sample download link: