Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
70156-1549 MS46SR-30-1570-Q1-1 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Ratings: 1 A at 30 VDC.
LED indicator: Without indicator.
Actuator: Crossroller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Classification: High-sensitivity.
Contact gap: H (0.25 mm).
Actuator: Low force wire hinge lever; Low OP.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available.
70156-1549 MS46SR-30-1570-Q1-1 Operation manual/Instructions/Model selection sample download link: