Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use
ZE-QA5-2
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, High-sensitivity.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
ZE-QA5-2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=ZE-QA5-2&select=5