Control power supply voltage: 100/110 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter
E2B-M30KS10-WZ-C2 5M
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 5 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Ordering Information.
Built-in Amplifier Photoelectric Sensors. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
E2B-M30KS10-WZ-C2 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2B-M30KS10-WZ-C2 5M&select=5