Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485
E2E-CR6C2 2M
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultCable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Transmits Input Device ON/OFF.
Signals and Power.
The Key to Effortless Wiring for.
Rotating and Moving Bodies. The ultra small size, high performance and rich models.
5.5mm ultra small built-in amplifier.
Maximum detection distance 2.5mm. Workpiece shaking can also be stable detection.
Response frequency 1kHz.
Low consumption current.
Category: DC 3 wire type.
Shape: non shield.
Detection surface: below.
Detection range: 1.6mm.
Output form: PNP.
Action mode: NO. Operating method: Incrementing and decrementing (selectable with DIP switch).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.
E2E-CR6C2 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-CR6C2 2M&select=5