Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 25 mm.
No. of opti- cal axes: 2.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 12 VAC/VDC
E2E-X4MD1-Z 2M
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Analog output (current output) (See note 2.).
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Transfer output (linear voltage output)(See note 2.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Platinum resistance thermometer.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
E2E-X4MD1-Z 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X4MD1-Z 2M&select=5