Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 300mmm.
Output mode: NPN output. Type: H5CX-L series.
Time specifications: 0
E2EF-QX12D1-M1TGJ 0.3M001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Input: Signal, Reset (NPN input).
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Appearance: Shielded, 5.4 dia.
Sensing distance: 1.5 mm.
Model: Operation mode, NC.
Subminiature Sensors with.
Long-distance Detection.
Shielded Sensor Heads from 3-mm to M12 diameters that,
can be embedded in metal.
Robotics cables provided as a standard feature (DC 2-Wire Models).
Indicator provided in Amplifier cable for easy confirmation of operation.
Power supply range of 5 to 24 VDC for DC 3-Wire Models. Control cycle: one year.
Output number: 4 channel.
Installation method: embedded installation.
Power supply voltage: AC100 ~ 240V.
Japanese label model.
The new standard for use of more convenient timing switches.
On the basis of a week of 2 channel type, the output of 4 channel type / year type also joined the series.
Use the independent key to improve the working performance significantly.
Holiday, holiday and other output OFF have a simple holiday set function.
Power OFF can also be set.
Test mode that can be easily recognized by the program.
In accordance with UL/CSA, electrical safety standard certification, EMC standards.
Industry first
Can reduce the set value, achieve fast setting!
The built-in temperature compensation circuit, even in a larger temperature range,
Can also achieve high time
E2EF-QX12D1-M1TGJ 0.3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2EF-QX12D1-M1TGJ 0.3M&select=5