LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
E3JK-TN14 2M Pirce
  • Brand: OMRON
  • Country: JAPAN
  • Name: Built-in Power Supply Photoelectric Sensor
  • Model: E3JK-TN14 2M
  • Price: 0
  • >
OMRON E3JK-TN14 2M
Appearance: Round/Full-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-G.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit E3JK-TN14 2M
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Optical system: positive and negative radiation.
Detection distance: 20 positive and negative 1mm.
Beam shape: linear beam.
Beam diameter: 1.0mm * 20 m.
Resolution: 0.25 M.
Cable length: 2m. Type: DC-switching.
Contact form: DPDT.
Open structure: Solder terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C. A collection of shell: the shell embedded R2 shell.
Purpose: high voltage PC (reactor) grounding system.
Static ground directional relay K2GS-B type,
Advanced ground direction relay corresponding to the diversification of ground fault.
Feeder priority cut-off function for coordinated multi segment setting.
Prevention of low frequency vibration with other circuit accidents,
Circuit for locking circuit and preventing effect of electric wave caused by false action,
In order to improve the reliability.
The coordination device for the zero phase action voltage is set up,
Therefore, the influence of the residual voltage can be avoided.
Due to the built-in filter, so in the event of the occurrence of the ramp wave input can also maintain a stable role,
Because of the signal level detection, it is easy to carry out the action experiment and set up the confirmation.
E3JK-TN14 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E3JK-TN14 2M&select=5


...more relevant model market price >>>>
Related products