Cable length L: A, 2.0 m; B, 1.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Number of connections to the image machine: 4.
Image storage function: up to 35 images can be stored.
Memory card slot: 2.
Monitor interface: composite video output: 1 channels. S video output: 1 channels.
Ethernet: 10 BASE-T:1 channels.
Parallel I/O:21 inputs and 46 outputs
E3T-ST31 2M Size: 48 x 48mm.
Control output 1: voltage.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility.
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow).
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. C500-NC Special I/O Unit Position Control For pulse motors 1 axis C500-NC113.Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
E3T-ST31 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3T-ST31 2M&select=5