E52-P35AY D=6.4 1M Pirce
OMRON E52-P35AY D=6.4 1M
Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits: Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches E52-P35AY D=6.4 1M
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Item: Advanced models, External input models.
Functions: Remote setting, Counter, Differential operation.
Model: PNP output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E52-P35AY D=6.4 1M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E52-P35AY D=6.4 1M&select=5


...more relevant model market price >>>>
Related products
OMRON
Temperature Sensor
E52-CA50AY D=6.4 1M
OMRON Temperature Sensor E52-CA50AY D=6.4 1M
Terminal type: Exposed-lead Models. Pro
OMRON
Temperature Sensor
E52-CA20AY D=6.4 1M
OMRON Temperature Sensor E52-CA20AY D=6.4 1M
Terminal type: Exposed-lead Models. Pro
OMRON
Temperature Sensor
E52-P50AY D=6.4 1M
OMRON Temperature Sensor E52-P50AY D=6.4 1M
Terminal type: Exposed-lead Models. Pro
OMRON
Temperature Sensor
E52-P35AY D=6.4 1M
OMRON Temperature Sensor E52-P35AY D=6.4 1M
Terminal type: Exposed-lead Models. Pro