Appearance: M18.
Sensing distance: 14 mm.
Connection method: M12 Standard Prewired Connector Models (0.3 m).
Cable specifications: PVC (oil-resistant).
Polarity: Yes.
Operation mode : NO .
Pin arrangement: 1: +V, 4: 0 V.
Applicable connector code: A.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
F2EL-X2F1-DS3SL
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NO.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Number of beams: 80.
Protective height: 1630mm.
Previously light curtains only offered status indicators.
The three types of indicators on the F3SR-B are not only,
status indicators but enable.
the user to completely understand the status at a glance,
further enhancing usability. Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 8, safety outputs (semiconductor): 8,
test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includes four models to accommodate various,
I/O types and number of I/O points.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system.
F2EL-X2F1-DS3SL Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F2EL-X2F1-DS3SL&select=5